Page 16 - catalogue-2024
P. 16

Genset Products / AMF Units



                                  DKG-105
                                  • Digital engine run-hours display
                                  • Automatic mains failure monitoring
                                  • Digital display of generator frequency
                                  • Provision for energize to stop, preheat &
                                     choke outputs
                                  • Digitally adjustable timers
                                  • Dimensions: 78x78x54mm (WxHxD)




                                                                                DKG-307
                                                                                • J1939 CANBUS or MPU input option
                                   DKG-107                                      • True RMS measurements
                                                                                • Genset kW and PF measurements
                                   • Automatic mains failure monitoring         • Battery backed-up real time clock
                                   • Automatic engine starting and stopping     • Weekly operation schedule programs
                                   • 3 phase mains voltage inputs               • Built in daily / weekly / monthly exerciser
                                   • 1 phase genset voltage input               • Event logging with time stamp and measurements
                                   • Dimensions: 72x72x52mm (WxHxD)             • RS-232 serial port
                                                                                • MODBUS  communication
                                                                                • Operating temp.: -40°C  to +70°C
                                                                                • Dimensions: 172x134x46mm (WxHxD)





                                     DKG-207
                                     • Genset kW and PF measurements(1phase)
                                     • Periodic maintenance request indicator
                                     • Logic level serial port used with the
                                        optional RS-232 adapter
                                     • Dimensions 133x107x39mm (WxHxD)







                                                                                DKG-309
                                                                                • J1939 CANBUS or MPU input option
                                     DKG-109                                    • True RMS measurements
                                     • J1939 CANBUS or MPU input option         • Multiple language support (TR, EN, CN)
                                                                                • Genset kW and PF measurements
                                     • True RMS measurements                    • Battery backed-up real time clock
                                     • Multiple language support (TR, EN, CN)   • Weekly operation schedule programs
                                     • Genset kW and PF measurements(1phase)    • Built in daily / weekly / monthly exerciser
                                     • Event logging with time stamp and        • Event logging with time stamp and measurements
                                        measurements                            • GSM SMS message sending on fault
                                     • Logic level serial port                  • GSM and PSTN modem support
                                     • Dimensions: 96x96x53mm (WxHxD)
                                                                                • MODBUS communication
                                                                                • Dimensions: 172x134x46mm(WxHxD)











            16  www.datakom.com.tr